Variable Sweep
(Available only in dual and tri-modes)
Range
0 to ±30 ìA
Sweep Rates
5 to 40 sec
Step Size
5 sec
Accuracy
±0.5 sec/sweep
Phase Shift
Range
0 to 120 degrees in 5 degree increments
(150 Hz phase relative to 90 Hz)
Accuracy
±0.5º
G/S MODE
TONE FREQUENCY ACCURACY
90 Hz ±0.02%
150 Hz ±0.02%
MODULATION
CAL
90 and 150 Hz Tones
40% AM , each tone
Accuracy
±2% modulation
Variable
Range
0% to 50% AM (90 and 150 Hz tones)
Distortion
<2.5% in CAL position
G/S DDM
Fixed
Range
±0, 0.091, 0.175 or 0.400 DDM and tone delete
Accuracy
±0.003 DDM (±2.5 ìA) ±3% of setting +10 dBm output level)
Variable
Range
±0.8 DDM in 0.001 DDM steps
Accuracy
±0.0048 DDM (±4.0 ìA) ±3% of setting +10 dBm output
level)
Phase Shift
Range
0 to 120 degrees in 5 degree increments
(150 Hz phase relative to 90 Hz)
Accuracy
±0.5º
MARKER MODE
MARKER TONE FREQUENCY ACCURACY
400 Hz ±0.02%
1300 Hz ±0.02%
3000 Hz ±0.02%
MODULATION
CAL
Setting
95% AM
Accuracy
±5% modulation
Variable (single carrier only)
Range
0% to 95% AM
Distortion
Single Carrier
<2.5% in CAL position (-67 to +10 dBm)
Tri-Mode
<5% in CAL position
COMM MODE (COMM AM, COMM FM, COMM SSB)
COMM TONE FREQUENCY ACCURACY
Pre-set (AM) 1020 Hz
±0.02%
Pre-set (FM) 1000 Hz
±0.02%
Pre-set (SSB) 1000 Hz / Variable (SSB) 25 to 3000 Hz
±6.25 Hz
Variable Steps (SSB)
25 Hz
AM MODULATION
CAL
1020 Hz tone
30% AM
Accuracy
±2% modulation
Variable
Range
0% to 95% AM (1% steps)
Distortion
<2.5% in CAL position
FM MODULATION
CAL
1000 Hz tone
5 KHz deviation
Accuracy
±0.5%
|
|