329.15 to 335.00 MHz with 90 Hz and 150 Hz tones, amplitude
modulated at 40% per tone. Variable and fixed DDM control is
provided.
Marker Beacon provides 75 MHz signal generation, amplitude
modulated at 95% with selectable 400, 1300 and 3000 Hz tones.
ILS provides simultaneous Localizer (with swept DDM), Glideslope
and Marker Beacon signals.
COMM AM provides signal generation and monitoring of transmitter
power and modulation depth over the range of 10.0000 to 400.0000
MHz. A 1020 Hz tone, amplitude modulated at 30% is also provided.
Frequency control is provided in 8.33 kHz / 25 kHz channel steps or
1 kHz variable steps.
COMM FM provides signal generation and monitoring of transmitter
power and FM deviation over the range of 10.0000 to 400.0000
MHz. A 1000 Hz tone, frequency modulated at 5 kHz deviation is also
provided. Frequency control is provided in 25/12.5 kHz channel steps
or 1 kHz variable steps.
COMM SSB provides signal generation and monitoring of transmitter
power and modulation depth over the range of 10.0000 to 30.0000
MHz. A 1000 Hz tone or variable tone 25 to 3000 Hz, SSB modulated
(LSB or USB), is also provided. Frequency control is provided in
100 Hz steps.
SWR provides selected CW frequency, SWR measurement or swept
SWR measurement over a 10.0000 to 400.0000 MHz range.
SELCAL (Selective Calling) provides selectable consecutive tone
pulse pairs which may be sent continuously or as a burst (VHF AM)
for testing SELCAL decoders.
MORSE CODE provides 1 - 4 characters transmitted in the VOR and
ILS localizer mode.
FREQUENCY COUNTER provides external frequency
measurement over the RF I/O connector and ANT connector from
10 to 400 MHz and over the AUX connector from 1 to 10 MHz.
121.5/243 BCN provides monitoring for 121.5/243 MHz swept tone
short range emergency beacons including monitoring of transmitter
power, frequency, AM modulation depth, modulation swept tone start
and stop frequencies. A headphone receive audio output is provided
via the Aux Port (requires user manufactured adapter cable).
406 BCN provides monitoring for 406 MHz COPAS/SARSAT
Emergency Locator Transmitter (ELT), Emergency Position
Indicating Radio Beacons (EPIRB and Personal Locator) PLB
Beacons including transmitter frequency and power. The beacon utilizes
BPSK data to transmit position information derived from a long
range navigation system or GPS receiver. All protocols defined in
COSPAS/SARSAT G.005 Issue 2 Rev 1 are supported. They consist
of 6 user protocols (plus a test protocol), 5 location protocols (plus a
test protocol). The Protocol management and data field decode is
automatically handled by the IFR 4000. Transmitter frequency andpower
are monitored.
SPECIFICATION
NOTE: A 15 minute warm-up period is required for all specifications.
RF SIGNAL GENERATOR
OUTPUT FREQUENCY
Marker Beacon Channel 72.0 to 78.0 MHz in 25 kHz steps
Marker Beacon Pre-set 74.5, 75.0 or 75.5 MHz
Marker Beacon Variable 72.0 to 78.0 MHz in 1 kHz steps
VOR Channel 108.0 to 117.95 MHz in 50 kHz steps
VOR Pre-set 108.0, 108.05 or 117.95 MHz
VOR Variable 107.0 to 118.0 MHz in 1 kHz steps
LOC Channel 108.1 to 111.95 MHz in 50 kHz steps
LOC Pre-set 108.1, 108.15 or 110.15 MHz
LOC Variable 107.0 to 113.0 MHz in 1 kHz steps
G/S Channel 329.15 to 335.0 MHz in 50 kHz steps
G/S Pre-set 334.25, 334.55 or 334.70 MHz
G/S Variable 327.0 to 337.0 MHz in 1 kHz steps
Comm AM Channel 10.0000 to 400.0000 MHz in 25 kHz steps,
118.0000 to 156.0000 in 8.33 KHz steps
Comm AM Preset 118.00, 137.00 or 156.00 MHz (VHF Band)
225.00, 312.00, 400.00 MHz (UHF Band)
Comm AM Variable 10.0000 to 400.0000 MHz in 1 kHz steps
Comm FM Channel 10.0000 to 400.0000 MHz in 12.5 or 25 kHz steps
Comm FM Pre-set 156.00, 165.00 or 174.00 MHz
Comm FM Variable 10.0000 to 400.0000 MHz in 1 kHz steps
Comm SSB Channel 10.0000 to 30.0000 MHz in 100 Hz steps
SELCAL Channel 118.0 to 156.0 MHz in 25 kHz steps
SELCAL Pre-set 118.0, 137.0 or 156.0 MHz
SELCAL Variable 117.0 to 157.0 MHz in 1 kHz steps
FREQUENCY ACCURACY
Same as time base
OUTPUT LEVEL
ANTENNA CONNECTOR
Single Carrier
10 MHz to 75 MHz
-17 to -67 dBm in 0.5 dB steps
75 MHz to 400 MHz
+13 to -67 dBm in 0.5 dB steps
Accuracy
±3 dB
Dual Mode - LOC
0 dBm fixed
Accuracy
±2.5 dB
Dual Mode - G/S
0 to -76 dBm in 0.5 dB steps
Accuracy
±3 dB
Tri-Mode - Marker
+13 dBm fixed
Accuracy
±2 dB
Tri-Mode - LOC
-7 dBm fixed
|
|