A powerful tool that can be used on the ramp or on the bench
Avionics
DT600 ARINC 429/629 DATABUS ANALYZER
The DT600 is a combination ARINC 429/629
databus analyzer with dual, independent ports
for each bus standard. Nearly identical functions
are provided for each bus type. These
include basic receive and transmit functions
along with a general record mode and a powerful
breakpoint mode. The standard RS-232
port is used for downloading real time or
recorded data and for uploading new
label/word definitions. The standard DAC port
can be used to provide a trigger pulse or to drive
recorders or instruments. An optional GPIB port
permits remote control of all functions. PC software
is available to aid the user in defining customized
data definition table(s). The large
graphical display and integrated keyboard provide
an informative and intuitive user interface.
FEATURES
• Two ARINC TX/RX ports and two ARINC
629 transceiver ports
• Operates six to eight hours on the internal
battery or power from external 28
VDC or 105-250 VAC
• Easy menu-driven setup allows intuitive
control of unit
• Multi-window display of data in ENGINEERING
(B777 default for 629), HEX,
BINARY, USER DEFINED, and GRAPHICAL
formats
• Powerful record and fault analyzer modes
• Williamsburg Protocol software extension
available for ARINC 429 file transfer functions
• RS-232C and DAC interface ports standard;
GPIB optional
• Software available for RS-232 port (download/
upload and word definitions)
GENERAL SPECIFICATIONS
ARINC 429 RECEIVER OPERATION
Ports
2
Bus Frequency
12-14.5 kHz or 100 kHz (selectable)
Input Levels
+ 6.5 VDC to + 13.5 VDC (A to B)
Input Impedance
12.0 K ohms
Word Update
1 ms to 10 sec, update rate displayed as instantaneous, min or max
value
Display Format
Pre-stored engineering units, hex, binary, user, ASCII, & graphic plots
Maximum Words
256 per SDI per channel
Bus Activity Monitor
Monitors loss of individual words; sensitivity selectable
Real-time Download/Conversion
RS-232C or 12-bit DAC port
ARINC 429 TRANSMITTER OPERATION
Ports
2
Bus Frequency
12.0 kHz, 12.5 kHz, 14.5 kHz, or 100 kHz (selectable)
|
|