Absolute accuracy (for RF signal & AWGN combined)
+18° to +28°C: ±1.0 dB
0° to +45°C: ±1.5 dB
REFERENCE SENSITIVITY LEVEL
RF signal power
-125 to -100 dBm/3.84 MHz
Absolute accuracy
+18° to +28°C ±1.0 dB
0° to +45°C ±1.5 dB
IUB INTERFACE
Format
E1, T1, E1 IMA, T1 IMA
E1 interface
75 Ù unbalanced,
120 Ù balanced
STM-1 interface
Single mode 1300 nm
INTERFACES
PC Interface
USB and Ethernet
External keyboard
PS/2 or USB
External mouse
USB
DIMENSIONS, ENVIRONMENTAL AND SAFETY
Typical weight (excluding accessories)
18 kg
Voltage Range
85 to 264 V AC
Frequency Range
45 to 66 Hz
Operating temperature
0° to 45°C
Storage temperature
-40° to 70°C
Altitude range
0 to 2000 m
Humidity
0 to 75%
Calibration interval
1 year
EMC
Complies with
EN61326-1:1997 + A1:1998 + A2:2001, Class A (emissions),
EN61326-1 :1997 + A1:1998 + A2:2001 Table 1 (immunity)
Safety
Complies with EN61010-1: 2001
Environmental Classifications
According to EN60721 'Classification of environmental conditions'
Exceeds the requirements of BS EN60721-3-7:1996 'Portable and
non-stationary use', classification IE73 (when used with the
Environmental protection case, Option 6413-Opt61)
Exceeds the requirements of BS EN60721-3-3:1996 'Stationary use
at weather protected locations', classification IE33
Exceeds the requirements of BS EN60721-3-2:1997 'Transportation',
classification IE21 (when suitably packaged)
Exceeds the requirements of BS EN60721-3-1:1997 'Storage', classification
IE11
|
|