Aeroflex 3065 PXI RF Combiners - AEROFLEX - #4

/ 8


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
Pages:


See other catalogues for AEROFLEX
You may also be interested in

Test set, Network tester, Antenna, Digitizer, Coupler


Text version of the page
Software The 3060 is supplied with a VXIpnp Driver and soft front panel. 3065 soft front panel Customer Support Users can elect to purchase PXI modules with optional warranty extensions. Standard Extended Warranty provides either 36 months or 60 months warranty period plus the benefits of guaranteed product repair times in the event of failure. Standard Extended Warranty can also be provided inclusive of scheduled calibration. On request Aeroflex can provide customized Premium Warranty support designed around your specific needs. SPECIFICATION Frequency Range All ports: 250 MHz to 6 GHz, useable to 70 MHz Insertion Loss Port A, B, C Switched to Ó Port C to Ó 250 MHz to 6 GHz <16 dB Port A to Ó 250 MHz to 2.7 GHz <15.5 dB 2.7 GHz to 6 GHz <17.5 dB Port B to Ó 250 MHz to 2.7 GHz <15.5 dB 2.7 GHz to 6 GHz <18.5 dB Ports Switched A-B or B-C (unswitched port routed to Ó) 250 MHz to 2.7 GHz <3 dB 2.7 GHz to 6 GHz <5 dB Ports C-D, A-D 250 MHz to 2.7 GHz <3 dB 2.7 GHz to 6 GHz <5 dB Calibration Uncertainty (23°C +/-5°C) Below 2.7 GHz 0.2 dB 2.7 to 5 GHz 0.3 dB 5 GHz to 6 GHz 0.4 dB Temperature Stability +0.006 dB/°C (A,B,C to SUM port) +0.002 dB/°C (all other paths) Repeatability Better than + 0.05 dB after warm up following a return from a change of mode valid for at least 2 hours and excluding temperature influence. Frequency Response (without correction) 250 MHz to 2.7 GHz <2.5 dB typical 2.7 GHz to 6 GHz <3.5 dB typical Return Loss (unused ports terminated into 50 ohms) Port Ó 250 MHz to 2.7 GHz >20 dB 2.7 GHz to 6 GHz >20 dB typical Port A - Ó >11 dB, typically 14 dB Ports B, C and D - Ó / A-B, B-C, C-D, A-D 250 MHz to 2.7 GHz >14 dB, typically 17 dB 2.7 GHz to 6 GHz >11 dB, typically 14 dB Isolation Between Ports (unused ports terminated into 50 ohms) A-B >30 dB, typically 35 dB All other ports >35 dB Max Power (Ó) +27 dBm, 3 VDC continuous +30 dBm MS 1:8 where M <0.5 ms Max Power (A, B, C, D) +24 dBm GENERAL Standard Warranty 24 months Calibration Interval Recommended 2 year Power Consumption (typical) +3.3 V <50 mA (transiently rising to 250 mA during power up) +5 V <50 mA +12 V <50 mA -12 V <50 mA Electromagnetic Compatibility EN 61326-1:1997, Emissions Class A, Immunity Table 1 – Performance Critieria B Safety EN 61010-1:2001 Safety requirements for electrical equipment for

pageCatalog pdf di En 2012-02-07-15