You may also be interested in
RF combiner, Antenna, Radio test set, Simulator, Digitizer
Text version of the page
Figure 2 – Transceiver testing
For intermod testing, two or three ports can be used to combine RF
source inputs to a common DUT test port. In this case the DUT
output port would be directly connected to the analysis instrument.
Figure 3 – Rx and Amplifier Intermod testing
Software
The 3060 is supplied with a VXI PNP Driver and soft front panel
Customer Support.
Users can elect to purchase PXI modules with optional warranty
extensions.
Standard Extended Warranty provides either 36 months or 60 months
warranty period plus the benefits of guaranteed product repair times
in the event of failure.
Standard Extended Warranty can also be provided inclusive of
scheduled calibration.
On request Aeroflex can provide customized Premium Warranty
support designed around your specific needs.
SPECIFICATION
Frequency Range
All ports: 250 MHz to 2.7 GHz, useable to 3.0 GHz
INSERTION LOSS
ABC - SUM
Loss between any of ports A, B, C and Ó port
<15 dB to 2.5 GHz and <16 dB above 2.5 GHz
A-B, B-C
Loss between ports A and B or B and C
<2 dB to 2.5 GHz
<3 dB above 2.5 GHz
Path Loss Calibration Uncertainty
<0.2 dB
Temperature Stability
+0.006 dB/0C (ABC to SUM)
+0.002 dB/0C (A-B, B-C)
Repeatability
Better than + 0.05 dB after warm up following a return from a change
of mode valid for at least 2 hours and excluding temperature influence.
Frequency Response
<2 dB typical
Return Loss
(unused ports terminated into 50 ohms)
Port Ó
>20 dB
Ports A, B and C (Connected to Port Ó)
>16 dB
>15 dB (A or C connected to B)
Port A, B, C Isolation (unused ports terminated into 50 ohms)
A-C >35 dB
A-B >35 dB
B-C >35 dB below 2 GHz otherwise >32 dB
Max Power (Ó)
+27 dBm, 3 VDC
Max Power (A, B, C)
A,B,C +17 dBm
GENERAL
Standard Warranty
24 months
Calibration Interval
Recommended 24 months
Power Consumption (typical)
+3.3 V <50 mA (transiently rising to 250 mA during power up)
+5 V <50 mA
+12 V <50 mA
-12 V <50 mA
Electromagnetc Compatibility
EN 61326-1:1997, Emissions Class A, Immunity Table 1 –
|
|