You may also be interested in
Software, Simulator, Chassis, Measuring device, Tester
Text version of the page
For the very latest specifications visit www.aeroflex.com
RS-232
25 way D-Type female, ISO 2110.
Mode
X.21 (X.24) Synchronous.
RS-449 (V.36) Synchronous.
Asynchronous.
V.35 Synchronous.
RS-232 Synchronous.
Asynchronous.
Implementation DTE.
DCE (Option).
Electrical
X.21 V.11 (Balanced).
V.10 (Unbalanced) (Option).
RS-449 (V.36) V.11 (Balanced).
V.10 (Unbalanced) (Option).
V.35 V.35 (data and timing).
V.28 (control lines).
RS-232 V.28.
Line Code
RS-232, V.35 NRZ.
X.21, RS-449 NRZ.
(V.10, V11) Biphase Mark.
Biphase Space.
Input Impedance
X.21, RS-449 (V.36)
V.11 Terminated 120 Ù
V.11 Unterminated >3000 Ù
V.10 >3000 Ù
V.35 100 Ù
Data Rate
V.11 50 bit/s to 2.5 Mbit/s
V.11 50 bit/s to 9 Mbit/s (option 26)
V.10 50 bit/s to 100 kbit/s.
V.35 50 bit/s to 2.5 Mbit/s.
RS-232
Async. 50 bit/s to 38.4 kbit/s
Sync. 50 bit/s to 80 kbit/s
Timing
Synchronous
Transmitter External, From DCE, Internal
Receiver External, From TX,
From DTE, From DCE.
Asynchronous
Transmit 50, 75, 100, 110, 134.5,
200, 300, 600, 1200, 1800, 2000,
2400, 3600, 4800, 9600, 19200,
38400 bit/s.
Receive Receive signal.
Polarity
The polarity of the transmitter incoming and outgoing clocks and the
receiver incoming clock can be selected.
Async coding
Data bits 5, 6, 7, 8
Stop bits 1, 1.5, 2
Parity Odd, even, none
Async character rate
Transmitter Selectable: low, medium, high
Receiver Up to 1000 characters/sec.
Receiver Clock Recovery
The receiver clock can be recovered from the data.
TEST PATTERNS
Sync and async.
PRBS
29-1, 211-1, 215-1, 220-1
Sense
True or inverted.
All Ones
Continuous sequence of 1111.
All Zeros
Continuous sequence of 0000.
Alternating
Alternating sequence of 1010.
Sync.
16 bit word
User programmable sequence of 16 bits.
8 + 8 word
Two user programmable 8 bit sequences are alternated by an external
TTL input. The changeover occurs at the end of 8 bits.
Async.
Fox Message
3 messages to ITU-T Recommendation R.52.
Fox 1
International alphabet 2.
Fox 2
International alphabet 5, 96 character set.
Fox 3
International Alphabet 5, 64 character set.
User message
1-19 characters.
ERROR INJECTION
Singly
By key press.
Fixed rate
Rate 3x10-1 to 1x10-7(sync only)
ALARMS
Line, Errors, Pattern.
SYNC OUTPUTS
PRBS transmit and receive.
Polarity
Negative pulse.
Interface
TTL
Pulse width
50% of bit interval.
|
|