HARDWARE OPTIONS TRACKING GENERATOR (2399C/1) Frequency Range 9 kHz to 3 GHz Output Level 0 to -70 dBm Output Level Resolution 0.1 dB step Absolute Level Accuracy ±1.0 dB at 0 dB Frequency Flatness 2.0 dB at -10 dBm Signal Purity Harmonics -15 dBc Non-harmonics -25 dBc Sub-harmonics -25 dBc Leakage -90 dBm HIGH STABILITY TIMEBASE (OPTION 03) Temperature Stability ± 0.2 ppm/°C 0°C to 40°C Ageing Rate ±0.1 ppm/yr QUASI-PEAK DETECTOR (OPTION 04) Quasi-Peak detector and EMC filters RBW 9 kHz Band B 120 kHz Band C Frequency Range 150 kHz to 30 MHz 30 MHz to 1 GHz Charge Time (ms) 1 ±20% 1 ±20% Discharge Time (ms) 160 ±20% 550 ±20% Display Time (ms) 160 ±20% 100 ±20% DIGITAL RESOLUTION BANDWIDTH FILTERS (OPTION 05) Bandwidths 100 Hz, 30 Hz, 10 Hz Bandwidth accuracy ±20% Selectivity (-60 dB/-3 dB) <5:1 Maximum span 1 MHz Sweep times for 10 kHz span RBW 100 Hz <0.9 sec. 30 Hz <3 sec. 10 Hz <4.5 sec. Displayed Average Noise Levels (DANL) between 1 MHz and 3 GHz reduces DANL by typically 5 dB from the values in the 300 Hz resolution bandwidth filter. AC/DC POWER SUPPLY (OPTION 6) DC Voltage 12 VDC to 21 VDC External Battery 14.4 VDC @ 7 AH Operation Time 1 Hour INTERNAL LOW NOISE PRE-AMPLIFIER (OPTION 07) Internally fitted option DANL Improves DANL by approximately 12 dB above 50 MHz Frequency Range 50 kHz to 50 MHz -115 dBm typical DANL 100 kHz to 1.8 GHz -130 dBm typical 1.8 GHz to 3 GHz -129 dBm typical Gain Compensated internally Selection User selected SOFTWARE OPTIONS DISTANCE TO FAULT (DTF) (OPTION 11) DISTANCE TO FAULT SPECIFICATIONS DTF Measurement Measurement Range Up to 99 km (324,720 ft.) depending on cable loss Units Meters or Feet Minimum Resolution For two equal amplitude discontinuities using maximum span: 13.24 x Vr cm Where Vr is the relative velocity factor for the cable. Maximum Measurement Update Rate 20 ms for 500 points Dynamic Range >60 dB Distance Accuracy 0.78 m for a single fault Transmission Line Database Data for common cables supplied as standard VSWR or Return Loss Measurement Calibration Open circuit or Short circuit Linearity As spectrum analyzer: <0.15 dB/dB, <1.5 dB over 10 divisions Accuracy Linearity + directivity + test port mismatch For Bridge 59999/170 at frequencies >50 MHz: Accuracy <0.01 + 0.032ñ2 + linearity Where ñ is reflection coefficient of system under test.

pageCatalog pdf di En 2012-02-07-15