You may also be interested in
Protocol analyzer, Testing machine, Electrical tester, RF combiner, Frequency counter
Text version of the page
For the very latest specifications visit www.aeroflex.com
abled.
External input
Rear panel BNC socket accepts an input at 1, 5 or 10 MHz with an
input level in the range 220 mV to 1.8 V RMS into 1 kŮ
GENERAL
GPIB INTERFACE
A GPIB interface is fitted. All functions except the supply switch and
display contrast are remotely programmable.
Capabilities
Designed in accordance with IEEE488.2.
Complies with the following subsets as defined in
IEEE Std. 488.1. SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, C0,
E2.
ELECTROMAGNETIC COMPATIBILITY
Conforms with the protection requirements of the EEC Council Directive
89/336/EEC. Conforms with the limits specified in the following standards:
IEC/EN61326-1 : 1997, RF Emission Class B, Immunity Table 1,
Performance Criteria B
SAFETY
Conforms with the requirements of EEC Council Directive 73/23 EEC
(as amended) and the product safety standard IEC / EN 61010-1 :
2001 + C1 : 2002 + C2 : 2003 for class 1 portable equipment, for
use in a Pollution Degree 2 environmen. The instrument is designed
to be operated from an Installation Category 2 supply.
RATED RANGE OF USE (Over which full specification is met)
Temperature
0 to 55°C.
Humidity
Up to 93% at 40°C.
CONDITIONS OF STORAGE AND TRANSPORT
Temperature
–40°C to +71°C.
Humidity
Up to 93% relative humidity at 40°C.
Altitude
Up to 4600 m (15,000 ft).
POWER REQUIREMENTS
AC supply
Four voltage settings covering:
100 V~ (Limit 90 - 115 V~)
120 V~ (Limit 105 - 132 V~)
220 V~ (Limit 188 - 242 V~)
240 V~ (Limit 216 - 264 V~)
Frequency: 50 - 400 Hz (Limit 45 - 440 Hz) 180 VA max
CALIBRATION INTERVAL
2 years.
DIMENSIONS AND WEIGHT
(Over projections but excluding handles)
Height Width Depth Weight
152 mm 425 mm 525 mm 21 kg
OPTIONS
OPTION 1 - SECOND MODULATION OSCILLATOR OPTION
Specification as Modulation Oscillator.
OPTION 2 - PULSE MODULATION OPTION
Modulation Modes
Pulse modulation may be used alone or in conjunction with ÖM, FM,
Wideband FM, Vector or Digital Modulation.
Rise/Fall Time
25 ns.
Control
0 V for carrier off, +5 V for carrier on.
Threshold level is typically +2.5 V.
ON/OFF Ratio
Better than 70 dB. Input impedance 50 Ů.
OPTION 105 - SLOW RISE TIME PULSE MODULATION
Modifies pulse modulation option for a typical rise and fall time of
1 ěs.
OPTION 6 - AVIONICS OPTION
See separate sheet.
OPTION 8 - RF PROFILE AND COMPLEX SWEEP
See separate sheet.
OPTION 12 - ELECTRONIC ATTENUATOR
Carrier Frequency Range
250 kHz* to 1.35 GHz (2050),
250 kHz* to 2.7 GHz (2051).
* Useable to 10 kHz (50 MHz in Digital or Vector modes, useable to
10 MHz)
RF Output
Range (Analog mode)
-138 dBm to +10 dBm When AM is selected the maximum output
level reduces linearly with AM depth to +4 dBm at maximum AM
depth.
Range (Digital or Vector mode)
-132 dBm to +3 dBm peak envelope power.
Accuracy
±1.2 dB in non Digital or Vector modes for output levels
> -127 dBm at 22°C ±5°C
Temperature Stability
±0.01 dB/°C
VSWR
< 1.5:1 for output levels less than 0 dBm.
Reverse Power Handling
1 W from a source VSWR of up to 5:1.
Amplitude Modulation
Standard specification applies for carrier frequencies above 50 MHz
(Above 100 MHz for Option 6).
|
|