You may also be interested in
Digitizer, Test system, Test set, Signal analyzer, Signal generator
Text version of the page
For the very latest specifications visit www.aeroflex.com
Timing jitter
±3.2 ěs
Filter
8th order Bessel, -3 dB at 3.9 kHz
PHASE MODULATION
Deviation
0 to 10 radians, 3 digits or 0.01 resolution
Accuracy at 1 kHz
±4% of indicated deviation excluding residual phase modulation
3 dB bandwidth
100 Hz to 10 kHz
Distortion
Less than 3% at 10 radians at 1 kHz modulation rate. Typically <0.5%
for deviations up to 1 radian at 1 kHz
Modulation source
Internal LF generator or external via front panel BNC
AMPLITUDE MODULATION
FOR CARRIER FREQUENCIES 2 GHZ
Range
0 to 99.9%, 0.1% resolution
Accuracy
±5% of set depth at 1 kHz (at +17°C to 27°C ambient temperature),
temperature coefficient <±0.02%/°C
1 dB bandwidth
DC to 30 kHz (DC coupled)
10 Hz to 30 kHz (AC coupled)
20 Hz to 30 kHz (AC coupled with ALC)
Distortion
<2.5%* at 1 kHz rate for modulation depths up to 80% and <1.5%
at 1 kHz rate for modulation depths up to 30%
*<3.5% for carrier freqs above 500 MHz
Modulation source
Internal LF generator or external via front panel BNC
PULSE MODULATION
FOR FAST PULSE MODULATOR SEE OPTIONS
Frequency range
32 MHz to 2.51 GHz, useable to 10 MHz
RF output range
Maximum guaranteed output is reduced to +8 dBm
(+20 dBm or +14 dBm with high power option when pulse modulation
is selected)
RF level accuracy
When pulse modulation is enabled, adds ±0.5 dB to the RF level
accuracy specification
On/off ratio
Better than 45 dB below 1.2 GHz, better than 40 dB above 1.2 GHz
Rise and fall times
Less than 10 ěs
Control
Pulse input is on a rear panel BNC with 10 kŮ nominal input impedance.
A HCT logic 0 (0 V to 0.8 V) turns the carrier off, a HCT logic 1
(2.0 V to 5 V) turns the carrier on. Max safe input is ±15 V
MODULATION OSCILLATOR
The modulation oscillator signal is available on a front panel BNC connector
at a level of 2 V RMS EMF from a 600 Ů source impedance.
Frequency range
0.01 Hz to 100 kHz
Resolution
5 digits. Minimum resolution 1 Hz
Frequency accuracy
As frequency standard
Distortion
Less than 0.1% THD at 1 kHz
Waveforms
Sine wave to 100 kHz
Square wave useable to 50 kHz
Triangle wave useable to 20 kHz
INTERNAL FUNCTION GENERATOR
In function generator mode, the modulation oscillator output may be
varied in frequency and level. Internal modulation is disabled in this
mode.
Level range
1 mV to 4 V RMS EMF
Resolution
1 mV
Source Impedance
600 Ů nominal
Level Accuracy at 1 kHz
±5% + 5mV
Frequency Response
Better than ±1 dB relative to 1 kHz
EXTERNAL MODULATION
Input on the front panel via BNC connector. 1 V RMS (1.414 V pk)
sine wave for set deviation. Input sensitivity may be optionally specified
for 1 V pk (option 10). Input impedance is 100 kŮ nominal.
MODULATION ALC
The external modulation input can be levelled by a peak levelling ALC
system over the input voltage range of 0.5 V to 1.25 V RMS sine
wave.
High and low indicators on the display indicate when the input is outside
the levelling range.
|
|