eXpert 26xx Universal Testing Machines - ADMET - #4

/ 4


catalogue search
P. 01
P. 02
P. 03
P. 04
Pages:


See other catalogues for ADMET

Text version of the page
eXpert 26xx Specifications
Model
2610
2611
2612
2613
2653
2654
2655
Table Top
Table Top
Table Top
Table Top
Floor
Floor
Floor
Load Capacity
lbf
1,125
2,250
5,000
10,000
10,000
20,000
30,000
kN
5
10
25
50
50
100
150
kgf
500
1,000
2,500
5,000
5,000
10,000
15,000
Maximum Speed
in/min
40
20
20
20
20
20
20
mm/min
1,016
508
508
508
508
508
508
Minimum Speed
in/min
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
0.0001
mm/min
0.0025
0.0025
0.0025
0.0025
0.0025
0.0025
0.0025
Maximum Force
lbf
1,125
2,250
5,000
10,000
10,000
20,000
30,000
at Full Speed
kN
5
10
25
50
50
100
150
Position Control
u in
2.7
2.7
2.7
0.56
0.56
0.56
0.56
Resolution
um
0.07
0.07
0.07
0.014
0.014
0.014
0.014
Total Crosshead
in
36
36
45
45
46
45
44
Travel1
mm
914
914
1,143
1,143
1,168
1,143
1,117
Total Vertical
in
41.3
41.3
51
51
51
50
49
Test Space2
mm
1,048
1,048
1,295
1,295
1,295
1,270
1,244
Lateral Test
in
__
--
--
--
--
Space
mm
--
--
--
--
--
--
Space Between
in
15.8
15.8
16.5
16.5
22
22
22
Columns
mm
400
400
420
420
558
558
558
Height
in
57
57
76
76
84
84
84
mm
1,448
1,448
1,930
1,930
2,133
2,133
2,133
Width (Frame Only)
in
32.5
32.5
34
34
41
41
41
mm
826
826
864
864
1,041
1,041
1,041
Depth
in
22.5
22.5
22.5
22.5
23
23
23
mm
572
572
572
572
584
584
584
Weight
lbf
330
330
600
600
1,600
1,800
2,000
kgf
150
150
275
275
730
820
910
Maximum Power
VA
300
300
500
800
800
1,400
2,000
Single Phase
VAC
110,220
110,220
110,220
110,220
110,220
110,220
220
Voltage
Hz
50,60
50,60
50,60
50,60
50,60
50,60
50,60
Load Measurement Accuracy: +/- 0.5% of reading down to 1/100 of load cell capacity. Meets or exceeds ASTM E4, BSENISO7500-1 : 2004, DIN 51221 and JIS B7721standards. ADMET self-identifying load cells are offered with all systems.
Strain Measurement Accuracy: +/- 0.5% of reading down to 1/50 of full scale with ASTM E83 class B extensometers. Meets or exceeds ASTM E83 and BSENISO9513 : 2002 standards.
Notes:
1) Total Crosshead Travel is calculated without load cells, grips and fixtures. Longer strokes can be accommodated by ordering an extended column frame.
2) Total Vertical Test Space is the distance from the top surface of the base platen to the bottom surface of the moving crosshead, excluding load cell, grips and fixtures. Larger openings can be accommodated by ordering an extended column frame.
Copyright 2008. All Rights Reserved. ADMET, Inc. Norwood, MA 02062 Rev. E

pageCatalog pdf di En 2012-05-21-25