You may also be interested in
Analyzer, Vibration analyzer, Monitoring system, Calibrator, Vibration monitoring system
Text version of the page
The only one difference between normal vibration measurement and machine deflection shapes measurement is the need to
measure more points on the machine. The use of the MDS method is not limited to experts. It is one way to evaluate data, which
can be used by everybody with a basic knowledge of vibration measurement. Adash Limited organises special courses connected
with MDS measurement. There are demonstrations and all questions and aspects of MDS method are explained.
MDS is a very sensitive tool for many types of machine failure which generate vibration in low and middle frequency bands.
MDS measurement does not operate in bearing failures (high frequency). All common failures as imbalance, looseness, misalignment
or a resonant problem can be indicated by MDS measurement.
The model shows a motor and a gearbox of a conveyer belt. Loosened
connection of the base girders with supports of the machine can bee
detected by using MDS.
A pedestal of a mill fan in a power station block. Looseness in the bearing
stand is evident after using MDS.
Trajectory of shaft vibration of turbine and generator in hydro-power
station.
The geometrical model of a primary ventilator in a CHP station block displays
an electric drive, two bearing housings and a fan section above the
metal pedestal. The measurement disclosed incorrect fastening of the
whole machine pedestal into the building floor.