& Technical Spécification:
|
|
|
|
|
|
|
|
|
1x (optional 2x) INPUT for vibration sensor (ICP power supply) or for AC input +3V TRIG for trigger impulses, machine speed (3 -5V)
RS 232 for optical tachoprobe, connector of communication interface with the user software RS 232 for communication with the user software
|
|
|
|
|
|
|
|
|
|
|
|
|
accelerometer with ICP power supply, nominal sensitivity 10, 50, 100, 500 mV/g or user setting
|
|
|
|
|
|
|
|
|
0.01 - 300 m/s2 (sensor 100 mV/g) 0.1 - 3000 m/s2 (sensor 10 mV/g)
|
|
|
|
|
|
|
|
|
LF velocity in mm/s in band 10 to 1,000 Hz, signal integrated
LIN acceleration in m/s2 in band 0.8 Hz to 16 kHz
HFE acceleration in g(g = 9.81 m/s2) in band 1.5 to 16 kHz
200Hz acceleration in m/s2 in band 0.8 to 200 Hz
ENV envelope in g (9.81 m/s2) in band 1.5 to 16 kHz
|
|
|
|
|
|
|
|
Balancing: velocity in mm/s in band 3 to 200 Hz (180 to 12,000 RPM), signal integrated
Measured data: values TRUE-RMS, TRUE-PEAK, Crest and Kurtosis factors, machine speed measurement of time signal, signal spectrum and order analysis one and two planes machine balancing, run-up and coast-down analysis
Averaging: maximum 20
Trigger: auto (internal), manually (key), external signal
Display: backlighted graphic LCD
Datamemory: 512 kB
Power supply: 4 x alkaline cells 1.5Vor accumulators 1.2 V (AA size)
Size: 223 x105 x40 mm
Weight: approx. 500 g
Protection: IP 55
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|