Untitled
measurements unlike manual probes (so-called vibration pens). The instrument enables to measure TRUE-RMS and TRUE-PEAK values, Crest factor and time signal in bands LF, LIN and HF (see below to the Technical Specification). The instrument works in the analyser mode and does not enable to store the measured data for further processing by the user software. This instrument is suitable for beginers and for maintanance staff.
Adash 4101 TREND Model:
It has all the characteristics of the 4101 BASE model, being further completed with a memory for route and on-line measurements. Only static data (RMS, PEAK, Crest, speed) can be stored, time signal cannot be stored. In addition, this
instrument includes the envelope analysis module. It works in the analyser and data collector modes and, if used with the DDS 2000 TREND user software, it enables to process measurement trends, to create route measurements and to process certificates and reports. If the processing of on-line measured data is sufficient in a text format, the simple A4000 DL user software can be used.
The instrument can also be completed with machine speed measurement, order analysis and the module of single and two plane balancing. Signal spectrum cannot be measured, with the exception of balancing spectrum. The instrument enables to trigger measurement by an external signal or tachoprobe impulses.
Adash 4101 Trend represents the base instrument for standard route vitration diagnostic.
Adash 4101 PRO Model:
It is the most efficient model among the Adash 4101 vibration analysers. Besides the possibilities of the 4101 TREND model, including all expansions, it also enables to measure the Kurtosis factor and signal spectrum via all four LF, HF, LIN and ENV signal paths. All types of dynamic data (time signal, signal spectrum, order analysis) can be stored in the analyser memory.
& Technical Spécification:
Inputs: INPUTforvibration sensor(ICPpowersupply)orfor ACinput + 3V
TRIG for trigger impulses, machine speed (3 -5V)
RS 232 for optical tachoprobe, connector of communication interface with the user software Interface: RS 232 for communication with the user software
Sensor: accelerometer with ICP power supply, nominal sensitivity 10, 50, 100, 500 mV/g or user setting
Signal ranges: 0.01 - 300 m/s2 (sensor 100 mV/g) 0.1 - 3,000 m/s2 (sensor 10 mV/g)
Signal paths: LF velocity in mm/s in band 10 to 1,000 Hz, signal integrated
LIN acceleration in m/s2 in band 0.8 Hz to 16 kHz
HF acceleration in g(g = 9.81 m/s2) in band 5to 16 kHz
ENV acceleration in m/s2 in band 5 to16 kHz, signal envelope modulated
Balancing: velocity in mm/s in band 10 to 200 Hz (600 to 12,000 RPM), signal integrated
Measured data: values TRUE-RMS, TRUE-PEAK, Crest and Kurtosis factors, machine speed measurement of time signal, signal spectrum and order analysis operating single and two plane machine balancing
Averaging: maximum 64
Trigger: auto (internal), manually (key), external signal
Display: backlighted graphic LCD
Datamemory: 512 kB
Power supply: 4 x alkaline cells 1.5Vor accumulators 1.2 V (AA size)
Size: 223 x105 x40 mm
Weight: approx. 500 g
Protection: IP 55
& Order Information:
The fully equipped measuring set Adash 4101 PRO includes:
- Adash 4101 vibration analyser
- analyser user's manual
- vibration sensor
- coiled cable for connection of the vibration sensor
- magnetic clamp for the vibration sensor
- optical or laser tachoprobe
- digital scales (for balancing)
- CD-ROM with the user SW (A4000 DL, DDS 2000, MDS 5.00 - as per order)
- RS 232 serial connection cable with Canon 9 terminals for communication with the user SW
- user SW manual
- 4 x accumulators AA 1.2 V
- battery charger with user's manual
- leather protective cover for the analyser
- transport bag with a strap
ADASH Ltd., Ostrava, Czech Republic, tel.: +420 596 232 670, fax: +420 596 232 671, email: info@adash.cz For further technical and contact information consult www.adash.net, www.adash.cz

pageCatalog pdf di En 2012-05-21-25