UPSon 300 High - AC/ DC Electronics - #2

/ 2


catalogue search
P. 01
P. 02
Pages:


See other catalogues for AC/ DC Electronics

Text version of the page
High Series
Uninterruptible Power Supply Technical Specifications
AC/DC UPS
MODEL
3100 3120 3160
3200 3250 3300
1 Power(kVA)
100 120 160 200 250 300
INPUT
Input Voltage
220/380 Vac 3 Phase + Neutral +/- %15
By-Pass Voltage
220/380 Vac 3 Phase + Neutral +/- %10
Input Frequency
50 Hz (Optional 60 Hz) +/- %5
EMC
EN50091-2 Class A
OUTPUT
Power(kW)
80 96 128 160 200 240
Power Factor
0,8
Voltage
220/380 Vac 3 Phase + Neutral
Voltage Tolerance
(Balanced Load +/- %1) (Unbalanced Load +/- %2) (Sudden Loading +/- %5)
Voltage Balance Time
Max. 25 msn. After Sudden Loading
Frequency
50 Hz (Optional 60 Hz)
Frequency Tolerance
(Synchronised to line: +/-%2) (Free Operation: +/-%0,2)
Efficiency (at % lOOLoad)
% 89-91 % 90-92
Crest Factor
3:1
Over Load
(at % 100-%125 load: 10 dk.) (at % 125-%150 Load: 1 dk.) (>% 150 Load: By-Pass)
Shortcircuit Protection
Available
THD
At Linear Load: < %3
THD
At Non Linear Load: < %5
BATTERY
Type
Dry Type Maintanence Free
Battery No
30
Charge Voltage
405VDC
End of Discharge Volta
|e 300VDC
Battery Protection
Automatic Circuit Breaker
Battery Test
Automatic Per 72 hours
DISPLAY
Type
5 Button and LCD
LCD Display
Input-Output Voltages, Frequency ,Load ,Battery Voltage and Charge Current, UPS inner heat and various alarms monitoring ON LCD Screen. Date and Hour Display: 64 recorded Alarm Memory
LED Display
LEDs for(Load at By-Pass, Load at UPS and Operation From Batteries)
GENERA
L
Serial Communication
DryContactand RS232
Software
T-MonUPS ManaqementSoftwcre
Operation Temperature
0C-40C
Cooling
Forced Cooling
Humidity (Not Condensed)
< 90 %
Protection Class
^^^^^^^^^^^^^^^m IP20
Operation Height
< 1000 m. From Sea Level
Noice Level
<65dBA
< 70 dBA
Weight (Without Battery)
770 810 960
1150 1285 1416
Dimensions(mm)H*W*L
^^^^^^^^^^^V 1650x1100x800
1730x1 195x870 | 1880x1565x925
OPTION
S
Input Transformer
Input Isolation Transformer
Input THDI
%10 (12 Pulse or 18 Pulse Rectifier, According to UPS Power)
%5 (18 Pulse Rectifier, + Filter), Upto 100 kVA
Input Power Factor
0.95-0.98 (Upto 100 KVAWith 18 Pulse Rectifier)
Parallel Operation
N+1 (Upto 4 Pcs)
Dimension Could be Different at18 Pulse UP
PerpaTicaret Merkezi ABIok Kat: 8 No: 851 Okmeydani 34384, istanbuI Tel :+90 212 320 20 07 Pbx Faks :+90 212 320 20 09 info@acdc.com.tr www.acdc.com.tr
AC/DC
ACDC Elektronik Sistemler Daniçmanlik San. ve Tic. Ltd. $ti.

pageCatalog pdf di En 2012-05-21-24