| | Input Voltage | 220 / 230 VAC-380 VAC/ 400 VAC | |
| | Voltage Tolerance | -5% +10% (±20%Optional) | |
| | Frequency | 50 Hz ± 5% (60 Hz ± 5% Optional) | |
| | Protection | Thermic - Magnetic & W. Automat Fuse | |
| | Power Factor | >0,8 | |
| | RECTIFIER OUTPUT | |
| | Output Voltage | 12VDC / 24 VDC / 48 VDC /110 VDC / 220 VDC | |
| | Charge Voltage Adjustment | ± 20 % Digitally Adjustable | |
| | Quick Charge Voltage | Digitally Adjustable Between 100% - 120% of Nominal Charge Voltage | |
| | Static Tolerance | 1% | |
| | Output Current Adjustment | 0-100% Digitally Adjustable | |
| | Output Fluctuation | Less than 5% of Output Voltage (RMS AC) (1% Optional) | |
| | Output Protection | Short Circuit / Overvoltage Protection / Reverse Voltage Protection | |
| | | |
| | Measurements | LCD Screen, CurrentVoltage and Time Display | |
| | Led Alerts | Quick Charge,Normal Charge,Current Control, Voltage Control, Charger On | |
| | Charge Method | Quick Float Charge, 3 Step Charge, Charge Programmable at10 Steps | |
| | Feeding Source | 0-100 Adjustable Voltage and Current Control | |
| | Button | Touch Screen Program Buttons | |
| | GENERAL | | |
| | Quick Charge Duration | Digitally adjustable between 0-600 mins with per 1 min. Sensibility | |
| | Cooling | With internal blower | |
| | Isolation Voltage | 3750 VAC Output -chassis | |
| | Efficiency | > 80% ( Full Load) | |
| | Input/ Output Connections | Screwed Rail Type Input - Output (Terminal) Blocks | |
| | Circuit Breakers | 2 Pes 2 Poled Thermic and Magnetic W-Automatic Fuse for Input and Battery (Load Fuse Optional) | |
| | Working Principle | Phase angle controlled tryhstor module charger | |
| | Protection Level / Color | IP20 (IP 32 Optional) / RAL7001 - RAL7032 | |
| | ALERT CONTACTS | | |
| | Sound Warning | »Beep« Alert Per2Seconds in Case of Failure | |
| | Charger Failure | LED warning and alert contact changes position in Case of DC High / Low,Output failure.Overheat, No line,Output short circuit (Optional) | |
| | DC Leakage | LED Warning and Alert Contact Changes Position in Case of DC Leakage to Ground Line at the (+)/(-) Output Edges (Optional) | |
| | Battery Low | Following to line voltage break,at the end of time varying upon battery group and load,alert contact changes it's position when the batteries reach the critical discharge levels (Optional) | |
| | ENVIRONMENTAL | | |
| | Operation Temperature | -10C/50 C | |
| | Relative Humidity | < 90% | |
| | Acoustic Level | <60dB(1m) | |
| | Working Height | < 2000 m | |
| | Electrical Standarts | EN 62040-1-1 (Security) | |
| | | | |