| | | AC/DC UPS | | |
| | | |
| | | |
| | | | | | | | | | | | | | | MODEL | 206 | 207 | 210 | 215 | 220 | 230 | | | | Power | 6 kVA | 7,5 kVA | 10 kVA | 15 kVA | 20 kVA | 30 kVA | | | | INPUT | | | | | Input Voltage | 220/380Vac3Phase + N+/-%15 | | | | By-Pass Voltage | 220 Vac+/-% 10 | | | | Current | 3x12A 3x15A 3x20A 3x30A 3x40A 3x60A | | | | Input Frequency | 50 Hz. +/- %5 | | | | EMI | EN50091-2 Class A | | | | OUTPUT | | | | | Power (kW) | 4,2 5,25 7 10,5 14 21 | | | | Power Factor | 0,7 | | | | Voltage | 220 Vac | | | | Voltage Tolerance | +/-% 1 | | | | Frequency | 50 Hz | | | | Frequency Tolerance | (Synchronised to Line): +/- 2% - (Free Operation): +/-%0,2 | | | | Efficiency (at % 100 Load) | %86-90 | | | | Crest Factor | 3:1 | | | | OverLoad | (at % 100-%125 Load: 10 minutes.) (at % 125-%150 Load: 1 minute.) (>% 150 Load: By-Pass) | | | | Shortcircuit Protection | Electronical Short Circuit Protection | | | | THD | <%3 | | | | Communication | DryContactand RS232 Communication | | | | Software | T-Mon Standart SNMP - ModBus (Optional) | | | | BATTERY | | | | | | Quantity | 20 | 30 | | | | Charge Voltage | 270VDC | 405VDC | | | | End of Discharge Voltage | 200VDC | 300VDC | | | | Battery Type | DryType Maintenance Free | | | | Battery Cabinet | Internal | | | | Operation Temperature | 25°C | | | | Battery Protection | Automatic Circuit Breaker | | | | Battery Test | | Optional | | * | Standart | | | | | | | | | | Operation Temperature | 0C-40C | | | | Noise Level | < 42 dBA | <42dBA | < 45 dBA | <45dBA | <45dBA | <45dBA | | | | Protection Class | ^^^^^^^^^^^^^^^^^^^^V IP20 | | | | Operation Height | < 1000 m.FromSea Level | | | | Humidity (Not Condensed) | < 90 % Max. | | | | Weight (Without Battery) | 50 | 55 | 55 | 65 | 91 | 112 | | | | Dimensions (mm) H-W-L | 540x265x560 | 540x265x560 | 710x265x740 | 710x265x740 | 710x265x740 | 710x265x740 | | | | OPTIONS | | | | | Input Transformer | Input Isolation Transformer | | | | PFC | ^ Input PFC{>0,97) | | | | Maintenance By-Pass | Isolation of UPS During Maintenance | | | | Parallel Operation | N+1 {Upto 4 Pes) | | | | | | | | | | | | | | |
| | | |
| | | PerpaTicaret Merkezi ABIok Kat: 8 No: 851 Okmeydani 34384, istanbuI Tel :+90 212 320 20 07 Pbx Faks :+90 212 320 20 09 info@acdc.com.tr www.acdc.com.tr | | |
| | | | | |
| | | |
| | | |
| | | | | | | | | | | | | |