| • 3I>, 31», 3I»> 50/51 3-phase non-directional overcurrent protection, 3 stages • 3I>-, 3I>>- 67 3-phase directional overcurrent protection, 2 stages •3I< 37 3-phase undercurrent protection •Io>, Io>>, Io>>> 50N/51N Non-directional earth-fault protection, 3 stages •I0>-, I0>>-, I0>>>- 67N Directional earth-fault protection, 3 stages •U0>, U0», U0»> 59N Residual overvoltage protection, 3 stages • 3U>, 3U>> 59 3-phase overvoltage protection, 2 stages • 3U<, 3U<< 27 3-phase undervoltage protection, 2 stages •3I2f> 68 3-phase transformer inrush and motor start-up current detector • AI> 46 Phase discontinuity protection •35 49F 3-phase thermal overload protection •0-1 79 Auto-reclosefunction (5 shots) • f</f>, df/dt 81U7810 Underfrequency/overfrequency protection • SYNC 25 Synchro-check/voltage-checkfunction •3J 49M/49G/49T Three-phase thermal overload protection for devices •Is2t n< 48/14/66 Three-phase motor start-up supervision •3I ^,3I^ 46R Phase reversal protection •I2>, I2>> 46 Negative phase sequence protection with two stages •U1<, U2>, U1> 27/47/59 Phase sequence voltage protection • FUSEF 60 Fuse failure protection • CBFP 62BF Circuit-breaker failure protection Included into every protection function Control Functions: I<->0 CB1 Circuit breaker control & indication with adjustable closing delay I<->0IND1-3 Objectlndication I<->0 POS Logic control position selection ALARM1-8 AlarmLEDs1-8 Monitoring and supervision: CB wear Circuit-breaker condition monitoring TCS1 Trip-circuitsupervision MCS 3I Energizing current circuit supervision MCS 3U Energizing current circuit supervision TIME1 Operation time counter Measurements: Primary and unitvalues 3I 3-phase current measurement I0 Neutral current measurement U0 Residual voltage measurement 3U 3-phasevoltagemeasurement f System frequency measurement E,P,Q,pf 3-phase power and energy (ncl. cos (p) DREC Transient disturbance recorder AI1 Analog measuring function PowerQuality: THD Current and voltage distortion measurements(1-13th harmonics) PQ3Inf Current waveform distortion measurement PQ3Unf Voltagewaveformdistortion measurement GENERAL: • Non-volatile memory • Ninedigital inputs • Four power outputs • Two signalling outputs • User-configurable Alarm LEDs • Internal relay fault output CCoEmCm0n7C0a-5o^CNon.^eSC^A:^ odbus. RTU/ASCII, DNP 3.0, Profibus-DPVI, IEC 61850 (with interface adapter) < • Connectivity package ; Dimensions: { Width148.8mm(1/3ofa19"rack), i Height frame 265.9 mm (6U) = Box 249.8 mm i Depth 235 mm i |