| • 3I>, 3I>>, 3I>>> 50/51 3-phase non-directional overcurrent protection, 3 stages • 3I>^, 3I>>^, 3I>>>^ 67 3-phase directional overcurrent protection, 3 stages • I(U)>, I(U)>> 51V Voltage-dependent overcurrent protection, 2 stages • Z<, Z<< 21 3-phase underimpedance protection, 2 stages •I0>, I0>>, I0>>> 50N/51G 3-phase non-directional earth-fault protection, 3 stages • I0,>^, I0>>^, I0»>^ 67N 3-phase directional earth-fault protection, 3 stages •U0>, U0>>, U0>>> 59N Residual overvoltage protection, 3 stages •P>W Q>^, P»W Q>>^, P»>W Q>»^ 32O 3-phase directional overpower protection, 3 stages •P<^, P<<^, P<<<^- 32R/32L 3-phase underpower/low forward power or reverse power protection, 3 stages • X<, X<< 40 Underexcitation protection, 2 stages • 3 j 49M/49G/49T 3-phase thermal overload protection for motors, generators or transformers •I2>, I2>> 46 Negative-phase-sequence protection, 2 stages • 3U>, 3U>> 59 3-phase overvoltage protection, 2 stages • 3U<, 3U<< 27 3-phase undervoltage protection, 2 stages • U1<, U2>, U1> 27/47/59 3-phase sequence voltage protection, 2 stages •f<, f>, df/dt 81U/81O Under- or overfrequency incl. rate of change, 5 stages •3AI> 87g 3-phase stabilized differential protection for generators •3A I> 87G/87M High-impedance or flux-balanced based differential protection for generators and motors • Mo 87N High-impedance based restricted earth-fault protection •3I2f>68 3-phase transformer inrush and motor start-up detector • 3Is2t, n< 48/14/66 Start-up supervision for motors • 3I<, 3I<< 37 3-phase non-directional undercurrent protection, 2 stages •3I , 3I r^, 46R Phase reversal protection • U/f>, U/f>> 24 Overexcitation protection, 2 stages • Synchro/voltage check 25 • Fuse failure supervision 60 • CBFP Circuit breaker failure protection 62BF Control • Circuit breaker with indication, 2 instances • Direct open for CBs via HMI • Disconnector with indication, 5 instances • 3-state disconnector with indication, 2 instances • Object status indication, 8 instances • On/off switch, 4 instances • Control position selector (remote/local/logic) • 8 Alarm LEDs with 3 colors and free text Measurement functions • 3I 3-phase current • Io, Uo Neutral current, residual voltage • 3U 3-phase voltage • E/P/Q/pf 3-phase energy/power/power factor • f System frequency • Transient distubance recorder Inputs/outputs - 15 or 25 freely assignable digital inputs - 5 or 11 power outputs for trip/close control; 2 of them with trip circuit supervision - 2 NO and 5 NO/NC signal outputs - 8 RTD/mA inputs, e.g. Pt100, Ni120, Cu10 and 4 isolated analog outputs 0/4-20 mA Energizing inputs - Conventional CT/VT inputs or current/voltage sensors - Several variants available, max 9 CT/VT inputs - Up to 8 current transformers for 1A and 5A connection - 1 current transformer for 0.2A and 1A connection - Up to 4 voltage transformers for 100V-120V connection - 9 inputs for current or voltage sensors Communication & Connectivity - SPA, LON®, IEC 60870-5-103, MODBUS® RTU/ASCII(1, PROFIBUS DP(2, DNP 3.0, IEC 61850(3 1) Requires the use of RS-232 to RS-485 converter module RER 133 2) With interface adapter SPA-ZC 302 3) With interface adapter SPA-ZC 400 - Connectivity package |