catalogue search
|
You may also be interested in
Digital flow-meter, Metering valve, Needle valve, Valve, Gas flow-meter
Text version of the page
WWW.AALBORG.COM - E-MAIL : INFO@AALBORG.COM - PHONE 845.770.3000 - TOLL FREE IN U.S.A. AND CANADA 1.800.866.3837 - ORANGEBURG N.Y. U.S.A. 34
PTFE - PTFA FLOW METERS L
**MATERIALS OF CONSTRUCTION
FLOW TUBES PFA.
FLOATS PTFE.
WETTED PARTS PFA (flow tubes) and PTFE (end fittings
and floats) and PCTFE (guide rods).
SPECIFICATIONS
SCALES 0 to 10 markings (see dimension table
for scale lengths).
ACCURACY ±5% of full scale.
MAXIMUM TEMPERATURE 250F F (121FC).
MAXIMUM PRESSURE 100 psig (6.7 bars).
LEAK INTEGRITY Individually pressure and leak tested and
certified to a rating of 1 x 10-7sccs of Helium.
PRINCIPLES OF OPERATION
A cylindrical float freely moving inside
a tapered flow tube comprises the
flow measurement element of PTFE -
PFA flow meters. The trans lucent PFA
flow tube is installed vertically in-line
in the liquid stream.
As flow takes place the float is propelled
up inside the flow tube. The
area between the float and the inside
diameter of the flow tube gradually
increases with increasing flow and
correspondingly the pressure lifting
the float decreases until the weight of
the float and its buoyant force come
to equilibrium.
At equilibrium the top
of the float is lined up
with a scale graduation
on the flow tube denoting
a discrete rate of flow.
MOUNTING DIMENSIONS
* Dimensions are in inches, except as shown in [mm]; for certified
dimensions contact the company.
**The selection of materials of construction, is the responsibility
of the customer. The company accepts no liability.
BULLETIN EM200910 L
|