You may also be interested in
Blower, Asynchronous motor, DC motor, Electric motor, Hermetic motor
Text version of the page
EPACT TEFC CCP JP FRAME 200-230/460 VOLT 2 Pole/3600 RPMCast IronIP 54 enclosure UL/CSA 4:1 constant torque/ 6:1 variable torque Continuous Duty Steel conduit box unattached in box New Replaces Gross Lifting Double Namplate Winding Bearing Bearings Bearings CHP Model # AOS # Efficiency Frame Weight Package Lugs Drill Base Data* Data* Type* DE ODE Dim. 3 TCP72004 N222 87.5 182JP 97 cardboard yes yes 1 3 5 6207ZZ 6206ZZ 20.86 5 TCP72005 N240 87.5 184JP 101 cardboard yes yes 1 3 5 6207ZZ 6206ZZ 20.867.5 TCP72006 N335 88.5 213JP 154 skid yes yes 2 4 5 6210ZZ 6208ZZ 24.9210 TCP72007 N346 89.5 215JP 176 skid yes yes 2 4 5 6210ZZ 6208ZZ 24.9215 TCP72008 N432 90.2 254JP 287 skid yes yes 2 4 6 6310 6208 29.7520 TCP72009 N433 90.2 256JP 322 skid yes yes 2 4 6 6310 6208 29.7525 TCP72010 N523 91.0 284JP 448 skid yes no 2 4 6 6310 6210 30.71 Shaft slinger NEMA MG 1-9 for noise Inverter Duty NEMA MG 1-7 for vibration1.15 Service Factor Nema B LRA 40ĖC Ambient Class F insulation 60Hz F1/F2 in field *Notes:1. 230/460 volt (60hz) w/full nameplate data; 200/400 volt 50hz with full data; 200 volt 60hz no nameplate data 2. 230/460 volt (60hz) w/full nameplate data; 200/400 volt 50hz with full data; 200/400 volt 60hz with full data3. 9 lead dual voltage 4. 12 lead dual voltage/capabaility of Y start-delta run 5. Double shielded bearings with no regreasing provisions 6. Open bearings with regreasing provisionswww.aosmithmotors.com 19 |
|