| | Feature | CODE | |
| | | REG-D™ | PAN-D | |
| | Analogue inputs and outputs without | E00 | - | |
| | Note: with 2 inputs | E91 | - | |
| | Please specify the scale if known!: with 4 inputs | E92 | - | |
| | with 6 inputs Example: with 2 outputs Channel 1: -100 ... 0 ... + 100 MW ... . ^ ,/Z, , - 20... 0 ... + 20 MW with 4 0utputs Channel 2: 0 ... 80 ... 100 V with 6 outputs 4 16 20 mA with 2 inputs and 2 outputs | E93 E94 E95 E96 E97 | - | |
| | Channel 3: 1... 19 tap-change positions with 2 inputs and 4 outputs | E98 | - | |
| | 0 ... 20 mA with 4 inputs and 2 outputs | E99 | - | |
| | Any combination on request | E900 | - | |
| | Note: each with 2 analogue inputs and outputs A total of 3 modules may be used. Pay atten- pj -|gg direct input tion to the ThAhA pM^ymm use of the Jap-change potentiometer input transformer monitoring module! i- » i- i- | | | |
| | Binary inputs (freely programmable) | | | |
| | E1...E8: 48..250 V AC/DC, E9...E16: 10 ... 50 V AC/DC (can also be used as a BCD input) | D1 | - | |
| | E1...E16: 48 ...250 V AC/DC (can also be used as a BCD input) | D2 | - | |
| | E1...E16: 10 ...50 V AC/DC (can also be used as a BCD input) | D3 | - | |
| | RS485 interface (COM 3) without | R0 | - | |
| | Note: with | R1 | - | |
| | COM 3 is only required for ANA-D and BIN-D! | | | |
| | Control system connection: Internal or external: | | | |
| | without (more in Feature Group "Y")) | XW0 | - | |
| | with integrated connection (more in Feature Group "XL") | XW1 | - | |
| | with ext. connection (REG-P/PE/PM) more in Feature Group "Y") | XW9 | | |
| | Integrated protocol interface card | | | |
| | for control connection of REG-D™ system | XL1 | - | |
| | for control connection of multiple systems | XL9 | - | |
| | Note: XL9 can only be combined with XZ15..XZ19 andXZ91 | | | |
| | Type of connection: | | | |
| | Copper | | | |
| | RS 232 | XV10 | - | |
| | RS 485 only for 2-wire operation | XV11 | - | |
| | Note: XV13 XV 19 can only be selected in combination with B02...B92. | | | |
| | In all other case, select the appropriate fibre optic cable module! | | | |
| | Fibre optic cable with FSMA connection | | | |
| | Glass fibre (wavelength 800...900 nm, range 2000 m) | XV13 | - | |
| | Plastic (wavelength 620...680 nm, range 50 m) | XV15 | - | |
| | Fibre optic cable with ST connection | | | |
| | Glass fibre (wavelength 800...900 nm, range 2000 m) | XV17 | - | |
| | Plastic (wavelength 620...680 nm, range 50 m) | XV19 | - | |
| | | | | |