Catalogue 4B Bin Switch - Capacitance Point Level Switch
www.go4b.com
print switch display
Page / 2
4B Braime Elevator Components -
/ 2
See other catalogues for 4B Braime Elevator Components
Text version of the page
Product Information
BINSWITCH
BRAIME
TECHNICAL SPECIFICATIONS
Type
BS12V10AI BS22V10AI
BS15V10AI BS25V10AI
Power Supply
24-240 Vac/dc
12-240 Vdc 24-240 Vac
Approvals
ATEX EX II 1D T100°C (Zone 20) IECEx Zone 20 & CSA |
Contact
Normally Closed Normally Open
Normally Closed 1 Normally Open
Max. Frequency
4 Hz
Protection
IP 65
Sensitivity
Detects up to 25 mm
Volt drop
8 V max.
Cable
2 wires, 5 m cable
5 wires, 5 m cable
Calibration
Turn sensitivty adjustment screw; the silo must be empty for calibration
Capacity
200 mA Max. Changeover relay rated at 3A 240Vac. Non inductiv
Ambiant
-15° to + 50°C
Temperature
CONNEXIONS
BS15V10AI
BS12V10AI
KIT CAPA
Brown
Black/orange\
12-240VDC 24-240VAC
Blue
Black
Î Black/red
Relay output 3A 240V Max
f Blue — 24-240V ac/dJ Black-
Load |200mA Max
BS25V10AI
BS22V10AI
- Brown
-r
AAWWWVVW
I
\
}_
J
J-
[AWUVvWYVWv
I Black/red
12-240VDC 24-240VAcS Blue
Relay output 3A 240V Max
Black
I black/orange
Blue-24-240V ac/dc<| Black
Load
200mA Max
Alignment belt sensor
Level or plug indicator
BS15V10AI OR BS12V10AI
BS15V10AI OR BS12V10AI
50 mm
BS25V10AI OR BS22V10AI
Please refer to instruction manual for correct installation. Information subject to change or correction. June 2006.
4B BRAIME ELEVATOR COMPONENTS LTD Hunslet Road, Leeds, LS10 1JZ, UK Tel:+44 (0) 113 246 1800 Fax: :+44 (0) 113 243 5021 4b-uk@go4b.com
www.go4b.com
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1