You may also be interested in
Vibration monitoring system, Vibration meter, Noise analyzer, Accelerometer, Test set
Text version of the page
Technical specifications of Wed007/dBLexd
01dB-Metravib
200, Chemin des Ormeaux
F-69578 Limonest Cedex
Phone: 04 72 52 48 00
Fax: 04 72 52 47 47
environment@01db-metravib.com
www.01db.com
Characteristics
Standards
Metrology
Precision class
Linearity domain
Dynamic range
Frequency weightings
Measured magnitudes
Configuration
Peak counting
Calculated magnitudes
Integration time
Memory module
General performances
Processing software dBLexd
Standard package
Wed007
CEI IEC 61252 (2002) / ANSI 1.25 (1991) / CEI IEC 61672-1 (2002)
CEM Radio ETSI EN 300 328 V1.5.1 (2004) / Emission CEI IEC 61000-6-3 /
CEI IEC 61000-6-4 / Reception CEI IEC 61000-6-1 / CEI IEC 61000-6-2
Leq / Lp channel Peak channel
Class 2
80 dB(A) 50 dB(C)
2 1 (fixed)
40-120 dB(A) / 60-140 dB(A) 93-143 dB(C)
45-120 dB(C) / 65-140 dB(C)
A and C in // C or Z
LAeq, LCeq, LASp, LAFp LCpk, LZpk
LASpmax, LAFpmax, LASeq, LAFeq
Tc, Lc, LCutoff, Q (3, 4, 5) 135, 137 and 140 dB
- Yes
Lex,d, EAT, Dose, SEL, LAvg, TWA,
Lex,8h, Projected dose, Lxx
From 1 s to 60 s
Microphone: type MCE321, class 2, 10 mV/Pa, 9 mm, weight 100 days
Typical operating life: 50 h (standard mode) / 10 h (remote control mode)
Parallel measurement and time history of all indicators
Pilot light indicating status
Integrated self-test
Keyboard locking
Control by Pocket PC: management of configurations / real-time display / data collection
Bluetooth wireless communication
Programmable start modes: manual / delayed / by periods
Visual display and coding of data on colour screen of Pocket PC
Preprogrammed set-up (type ISO85, OSHA,…)
Mode Leq (Start/Stop)
Written and voice comments (synchronised with measurement file)
PC-compatible software
Language: English, French
Compliant with Standards NF S 31-084 (2002) and ISO 9612 (1997)
Transfer of measurement sessions
Importation of 01dB measurement sessions (compatible with SIE95/CLS95/*.cmg and *.sip files)
Start in simplified mode
Visual display of time histories
Coding of periods
HEG management (tasks or operations)
Calculation of noise exposure parameters according to standards
Printing of results as standardised sheets
Automatic reports
Storage of projects
Dosimeter Wed including a MCE321-type microphone with integrated preamplifier and tie clip
1-m extension cable
Acoustic calibrator
Table charger with mains power supply (1 unit or 5 units depending on version)
Hook and loop armband
Carrying case
Pocket PC Win CETM with software dBWed
Processing software dBLexd
User manual
The presented characteristics are subject to change without notice. Version March 2007
Operating software dBWed
|
|